Analog to rs485 converter can be achieved between the sensor and the host signal acquisition, used to detect analog signals. Application in the 485 bus industrial automation and control systems, can monitor 4 ~ 20mA / 0 ~ 5V / 0 ~ 10V signal. Safe, reliable, beautiful appearance, easy installation.
- Model: VRS-&-485-&-EX
- موك: 1 قطعة
- تاريخ التسليم: خلال 24 ساعة
- استفسر عن السعر الآن
الاستفسارات: البريد الإلكتروني: contact@veswe.com | WhatsApp: +8613418148929
About Analog to RS485 Converter
analog to rs485 converter using the standard Modbus-RTU protocol, address, baud rate can be set by the host computer software that can be articulated in the 485 bus. Products according to industry-standard design, manufacture, with over-voltage protection, over-current protection, anti-interference ability, high reliability.
Analog to RS485 Parameters
Power supply: DC 10~30V
Number of input channels: 1-way or 2-way optional
Acquire the Signal: 4-20ma/0-10v/0-5v
Protocol: MODBUS-RTU
Input resistance: 4-20ma ≤200 ohms,0-5v/0-10v≥10K ohms
Power consumption: 0.4w
Signal output: RS485
AD conversion resolution: 10-bit or 12-bit optional
Storage environment: -20℃~+60℃
Analog to RS485 Converter Use
- Intelligent building control, security, and engineering applications
- Industrial sites, power distribution cabinets, and other places that require an RS485 output
- Debugging and control of equipment operation
- Medical machine monitoring
- Sensor signal to restore the long-range transmission and signal
- Industrial field data for a given actuator
Wiring - 4 20mA/0-5V/0-10V to RS485
Wiring instructions
| Types | Logo | الوصف | Remarks |
|---|---|---|---|
| Power input and communication | VCC | Power input positive | 10 ~ 30 فولت تيار مستمر |
| GND | Power input ground | ||
| 485A | 485-A | Communication | |
| 485B | 485-B | ||
| Power output and signal input | VCC | Power output positive | Power output, module to equipment |
| GND | Power output ground | ||
| IN0 | Analog 1 input | Common for two-wire, three-wire, and four-wire system | |
| IN1 | Analog 2 input |
The conversion module only needs one end of the power supply to be able to work normally, and the other end of the power supply is prepared for the subsequent stage power supply. If the latter stage is not powered, it can be left floating.
When multiple 485 models are connected to the same bus, there are certain requirements for on-site wiring, please contact us for details.
Input signal wiring example
| Wire system | VCC | GND | IN0 | IN1 |
|---|---|---|---|---|
| Two-wire system | Device power is positive | Air | Analog input 1 | Analog input 2 |
| Three-wire system | Equipment power ground | Analog input 1 | Analog input 2 | |
| Four-wire system | Equipment power ground analog input negative | Analog input 1 positive | Analog input 2 positive |