TVOC-Sensor
The Veswe TVOC Sensor (VRS-TVOC-&-2-4-EX) is an industrial-grade air quality monitor designed for real-time detection of total volatile organic compound levels. It seamlessly connects to our free cloud platform, allowing you to remotely access and monitor data anytime, anywhere.
Featuring flexible RS485 (Modbus) and analog output options, it easily integrates with existing control systems to meet diverse user requirements. Housed in a rugged, wall-mounted waterproof enclosure, this sensor delivers reliable performance even in harsh, dusty industrial environments, making it ideal for factories, workshops, and commercial buildings.
- Model: VRS-TVOC-&-2-4-EX
- MOQ: 1 STK.
- Liefertermin: innerhalb von 24 Stunden
- Jetzt Preis anfragen
Anfragen: E-Mail: contact@veswe.com | WhatsApp: +8613418148929
Industrial-Grade Total Volatile Organic Compounds Monitor
Meet the Veswe TVOC Sensor, a high-performance transmitter designed to detect and measure total volatile organic compounds in real time. Capable of monitoring concentrations from 0 to 60,000 ppb with 1 ppb resolution, this TVOC sensor is critical for safeguarding human health in
indoor environments. Whether you need a rugged VOC sensor for a factory floor or a precise volatile organic compound sensor for a lab, this unit delivers ±8% FS accuracy. Refreshing data every second, this TVOC sensor ensures no harmful spike goes unnoticed. Operating reliably from -40°C to +80°C, it stands as the ultimate VOC sensor for extreme conditions. With multiple output options (RS485, 4-20mA, WiFi), this tvoc detector integrates seamlessly into any BMS or SCADA system. Trust this tvoc meter to provide the clarity you need for safety compliance.

Six Key Advantages – Reliability & Resilience
Why choose our TVOC sensor? It offers six core advantages tailored for demanding deployments:
High-Quality Detection: Uses precision NDIR/PID technology, making this VOC sensor incredibly accurate.
GPS Positioning: Optional geotagging helps track assets, enhancing the utility of your tvoc monitor network.
IP65 Protection: Fully sealed against dust and water jets, ensuring this tvoc detector survives outdoors.
Free Cloud Platform: Upload data to our dashboard, turning your tvoc air quality checks into actionable insights.
Fearless of Condensation: Internal design prevents moisture buildup, a common failure point for ordinary voc meter units.
Strong Anti-Interference: Shielded circuitry resists electromagnetic noise, guaranteeing stable output from this voc detectors (plural context: “array of voc monitors” -> let’s use specific keyword) -> Correction: guaranteeing stable output from this voc monitors setup.
From factories to server rooms, this TVOC sensor is built for resilience. As a reliable volatile organic compound sensor, it protects productivity. Whether deployed as a single sensor voc node or a grid of voc monitors, it ensures air quality remains safe. This tvoc monitor is the backbone of modern industrial hygiene.

Flexible Signal Output Options
Integration flexibility defines our TVOC sensor. Supporting seven versatile output types, this VOC sensor adapts to any architecture:
Wired Protocols: RS485, 4-20mA, 0-5V/10V. Perfect for connecting a tvoc meter to legacy PLCs or DCS systems.
Wireless IoT: 4G, WiFi, LoRaWAN. Enables remote tvoc air quality monitoring without cabling, ideal for distributed sites.
Whether you need a simple voc meter for local logging or a complex voc detector network for enterprise control, the choice is yours. Configure your TVOC sensor via software or dip switches. For custom protocol mapping, this sensor tvoc solution offers endless possibilities. As a versatile voc gas detector, it bridges the gap between old infrastructure and new IoT capabilities. Every sensor voc installation benefits from this plug-and-play design.

Rugged IP65 Enclosure for Harsh Environments
Durability is non-negotiable. The housing of our TVOC sensor meets strict IP65 standards, meaning it is dust-tight and protected against water jets.
All-Weather Operation: Functions flawlessly in rain, snow, and humidity, making this VOC sensor perfect for outdoor agricultural sheds.
Dust Resistance: Ideal for mining facilities or dusty manufacturing floors where a standard tvoc detector might fail.
No Extra Enclosures: Install this tvoc meter confidently anywhere, from cold storage to food processing plants.
Visual tests show water splashing harmlessly around the unit, proving its resilience. This tvoc monitor requires no additional protection. As a robust voc air quality monitor, it withstands the elements. Whether you call it a voc gas detector or an environmental shield, its performance is unmatched. Trust this TVOC sensor to keep working when others quit.

Multi-Scenario Deployment Across Industries
Where does a TVOC sensor make the biggest impact? Everywhere air quality dictates safety.
Greenhouses: Monitor off-gassing from fertilizers with a sensitive VOC sensor.
Utility Tunnels: Detect hazardous leaks before they become toxic, using a responsive tvoc detector.
Warehouses: Ensure safe conditions amid solvents and refrigerants with a reliable tvoc meter.
Data Centers: Prevent equipment corrosion by tracking airborne contaminants with a precise tvoc air quality tool.
Real-time alerts notify managers when thresholds are breached, triggering ventilation automatically. This tvoc monitor capability saves lives. From a single voc meter spot-check to a fleet of voc monitors, our solution scales. As a specialized volatile organic compound sensor, it addresses unique industry risks. Whether deployed as a sensor voc node or a voc detector array, it ensures compliance. This sensor tvoc is the key to safer workplaces. Don’t gamble with invisible gases; choose a proven voc gas detector and a comprehensive voc air quality monitor strategy today.

View - TVOC sensor
Environmental pollution caused by interior decoration has attracted more and more attention, and TVOC is the most serious of the three organic pollutants (polycyclic aromatic hydrocarbons, volatile organic compounds, and aldehydes) in the air. VOC refers to organic substances whose saturated vapor pressure exceeds 133.32pa at room temperature, its boiling point is between 50°C and 250°C, and exists in the air in the form of evaporation at room temperature. Its toxicity, irritation and carcinogenicity can affect the skin and mucous membranes, cause great damage to the human body. The TVOC sensor launched by our company can effectively monitor the TVOC content in the environment.
Description of TVOC sensor
The TVOC sensor collects data and uploads the data to the cloud platform through the concentrator. The cloud platform supports computer terminal and mobile terminal login. Users can log in anytime and anywhere through the account password to view the real-time and historical data of indoor TVOC gas concentration.
Through the cloud platform, we can set the upper limit alarm value of indoor TVOC gas concentration. For example, the alarm value is set to 0.28mg/m³. If the TVOC gas concentration approaches or reaches the limit value, the cloud platform will send a platform alarm, SMS alarm, email alarm, etc. Notify the manager as soon as possible and take timely measures to reduce the TVOC gas concentration.
Wall mounted TVOC sensor
- Stromversorgung: DC 10-30V
- Working environment: -40℃~+80℃, 0%RH~95%RH non-condensing
- Range: 0~60000ppb
- Measurement object: volatile organic compounds
- Resolution: 1ppb
- Datenaktualisierungszeit: 1s
- Accuracy: 8%FS(@C2H6O,0.5ppm,25℃,50%RH)
- Output signal: RS485/4-20mA/0-5V/0-10V
- Installation method: wall-mounted installation
- Preheating time: ≤24h
Fixed TVOC detector
- Stromversorgung: DC 10-30V
- Working environment: -20℃~+60℃, 0%RH~95%RH non-condensing
- Range: 0~60PPM
- Measurement object: total volatile organic compounds
- Resolution: 0.001PPM
- Accuracy: 8%FS(@C2H6O,0.5ppm,25℃,50%RH)
- Output signal: RS485/4-20mA/0-5V/0-10V
- Preheating time: ≤1 hour
- Explosion proof mark: Ex d IIC T6 Gb
- Relay with load capacity: 250VAC 1A/30VDC 3A
FAQs
Usually, we call formaldehyde, benzene, ammonia, xylene and other volatile gases in the indoor environment TVOC gas.
0.5 mg/m3
“According to the specified standard, the safe value of one cubic meter of TVOC should be within 0.5mg/m3. If the measured TVOC value exceeds this standard, it means that the pollution in the air is relatively serious.
TVOC can cause serious indoor air pollution and cause imbalance of human immune level. Affect the function of the central nervous system, causing headache, weakness, chest tightness and other symptoms. It may also affect the digestive system, resulting in loss of appetite and nausea. In severe cases, the liver and hematopoietic system can be damaged.
An TVOC sensor is used to detect Total Volatile Organic Compounds in your environment. It does this by identifying vapours of gases given off by volatile compounds.
The sum of all VOCs is called total volatile organic compounds (TVOC). The gas volume of each category and the sum of all gases (TVOC) is an important reflection of the relevant organic compounds found in indoor air.
The working principle of the Tvoc sensor is relatively simple. When the detected gas exists in the air, the conductivity of the sensor changes. The higher the concentration of the gas, the higher the conductivity of the sensor.
According to the different installation methods in different places, it can be roughly divided into three types: wall-mounted TVOC meter, explosion-proof TVOC gas detector, and portable TVOC gas detector
TVOC gas detector is suitable for oil extraction, smelting, chemical industry, municipal administration, sewage treatment, power gas, mining, tunnel construction, fire storage, papermaking, pharmaceutical, brewing and other environments that need to detect toxic and harmful gases for work!
The calibration of tvoc meter is technical work, please contact professional technicians.