Capteur de turbidité
The turbidity sensor is a water quality sensor that utilizes an RS485 communication interface and the standard Modbus protocol. It uses an infrared LED with a wavelength of 860nm as the light source, which is not affected by the color of the water sample. The turbidity probe is equipped with an automatic cleaning brush, and the housing is waterproof with a high protection rating of up to IP68. The turbidity sensor can be used for measuring rivers and streams, wastewater and sewage, sedimentation tank control, sediment transport research, and laboratory measurements.
- Model: VRS-ZD-N01-&-EX
- MOQ : 1 PCS
- Date de livraison : dans les 24 heures
- Demander le prix maintenant
Renseignements : Courriel : contact@veswe.com | WhatsApp : +8613418148929
See Through the Chaos: The Veswe Digital Turbidity Sensor
Advanced Optical Technology & Stability
Built for the Deep End: Durability & Design
Self-Cleaning Intelligence for Low Maintenance
Versatile Applications & Smart Integration
- Wastewater Treatment: Monitoring effluent clarity and sedimentation tank performance.
- Aquaculture: Ensuring optimal water clarity for fish health.
- Environmental Protection: Tracking pollution levels in rivers and lakes.
- Industrial Processes: Controlling dosing systems based on real-time turbidity monitoring.
Precision Calibration & Ease of Use
- Principle: 90° Light Scattering (Nephelometric)
- Light Source: 860nm Infrared LED (Color Independent)
- Protection: IP68 (Up to 20m depth)
- Features: Auto Cleaning Brush (Optional), Temp Compensation
- Output: RS485 (Modbus-RTU)
- Material: Corrosion-resistant Plastic or Stainless Steel
Don’t let murky water obscure your data. Equip your team with the Veswe Capteur de turbidité. It combines the precision of a lab-grade turbidity analyser with the ruggedness of an industrial water sensor. Whether you need a robust inline turbidity meter for continuous flow or a stationary turbidity probe for deep-water monitoring, this device delivers the clarity you need to make confident decisions.
View - Turbidity Sensor
Turbidity is caused by suspended particles in water, which scatter the incident light. Typically, a 90-degree angle scattering light is used as the testing signal. The relationship between scattered light and turbidity follows a multi-segment linear relationship, requiring the turbidity sensor to be calibrated at multiple points. Additionally, variations in light source intensity and temperature can affect the accuracy of measurements. Through multiple experimental studies and calculations, we have developed a turbidity sensor with temperature compensation capability, high accuracy, and good stability.
VRS-ZD-N01-EX is an online water quality monitoring digital turbidity sensor. It adopts the mature 90° scattering light principle and incorporates fiber optic technology into the turbidity sensor, providing superior repeatability and stability while being less susceptible to environmental light interference. When used in conjunction with the sensor’s automatic cleaning brush, it effectively removes bubbles and reduces the impact of contamination on measurements, prolonging the maintenance cycle and maintaining excellent stability even during long-term online use. The sensor also incorporates a built-in filter algorithm, enhancing its resistance to external light interference. It features a built-in temperature transmitter that enables automatic temperature compensation, making it suitable for long-term online monitoring in various environments.
Turbidity Sensor Datasheets
| Alimentation électrique | DC 10~30V |
| Consommation électrique | 0.2W |
| Plage de mesure | 0.00~50.00NTU; 0.0~200.0NTU; 0.0~1000.0NTU; 0~4000NTU |
| Précision | ±5%FS (25°C); ±0.5°C |
| Résolution | 0.01NTU(0.00~50.00NTU); 0.1NTU(0.0~200.0NTU); 0.1NTU(0.0~1000.0NTU); 1NTU(0~4000NTU); Temperature: 0.1°C |
| Temps de réponse | ≤30sec |
| Working condition | 0~40℃ |
| Principe de fonctionnement | 90° light scattering method |
| Using life | 2 years in normal use |
| Protect class | IP68 |
| Wire length | default 5m (customized) |
| Matériau du boîtier | Corrosion-resistant plastic |
Turbidity Sensor Advantages
1.The monitoring principle of 90-degree angle scattering light ensures accurate and stable measurements and is suitable for long-term online monitoring in various environments without being affected by magnetic fields.
2. It has a built-in temperature transmitter with automatic temperature compensation function, reducing the interference of temperature on measurement results.
3. It adopts a fiber optic structure, which has strong resistance to external light interference.
4. The infrared LED light source provides high stability, convenience, speed, and ease of maintenance.
5. The turbidity sensor undergoes strict calibration before leaving the factory, eliminating the need for secondary calibration. It can be used immediately upon receipt, allowing for quick deployment.
6. It has an IP68 protection rating, with waterproof housing that enables normal usage in water depths of up to 20 meters.
7. The surface of the turbidity probe is treated with corrosion and passivation, ensuring a lifespan of 2 years or more.
8. The turbidity sensor adopts a 3/4NPT tapered thread, making installation and fixation more convenient
Turbidity Sensor FAQs
A turbidity sensor is a device that utilizes optical principles to measure the turbidity of water. The lower the amount of light that can pass through, the higher the turbidity of the water sample. It is widely used in areas such as water quality monitoring, wastewater treatment, water treatment plants, and water feature engineering.
- Place the turbidity sensor into a standard turbidity solution with a value of 0 NTU (deionized water). Calibration can be performed in a dark and clean air environment with less stringent requirements. Once the reading becomes stable, send the zero-point calibration command.
- Next, place the turbidity sensor into a standard turbidity solution corresponding to the maximum range. Once the reading becomes stable, send the full-scale calibration command to complete the turbidity calibration.
- Note: During the calibration process, ensure that there are no bubbles attached to the optical window of the transmitter. Maintain a distance of at least 7 cm between the transmitter and the bottom of the container.
- Please do not attempt to open or repair the turbidity meter yourself in case of any noticeable faults. Contact us as soon as possible for assistance.
- Before taking measurements, remove the black rubber protective cover.
- Regularly clean the adhered substances on the sensor probe according to the usage environment, as they can cause measurement errors. Avoid scratching the light-guiding part of the probe during cleaning. (It is recommended to clean every 30 days)
- It is recommended to rinse the outer surface of the turbidity sensor with running water. If there are still residues, use a soft damp cloth to wipe it clean.
- Calibrate the device before each use, and for long-term use, it is recommended to calibrate every 3 months. The calibration frequency should be adjusted accordingly based on the specific usage environment (degree of dirtiness in the application, deposition of chemicals, etc.).
- When a beam of light is directed into a water sample, the turbidity particles in the water cause the light to scatter. By measuring the intensity of the scattered light in the direction perpendicular to the incident light and comparing it with internal calibration values, the turbidity of the water sample is calculated. The final value is obtained through linearization processing and is outputted as the result.
Our turbidity sensor comes with an NPT 3/4 thread, which can be used in conjunction with our waterproof conduit. The cable should be threaded through the conduit, and the turbidity sensor can be screwed into the thread of the waterproof conduit.
Note: Install the turbidity sensor in an area with slow water flow and no bubbles. Maintain a distance of 5 cm from surrounding walls during installation, and ensure that there are no obstacles within 7 cm below the sensor.
Temperature variations have an impact on the electrical output of the sensor. Even if the turbidity level remains constant, fluctuations in temperature can alter the turbidity readings. This influence can be addressed by incorporating a temperature compensation feature.
Autres capteurs de qualité de l'eau
Connaissance du secteur
Les 3 principaux types de paramètres de qualité de l'eau | Capteurs de surveillance de la qualité de l'eau Veswe
Contactez nous
Notre collègue : Jack
Téléphone/ Whatsapp : +86 13418148929
Courriel : contact@veswe.com
Adresse : Floors 1-4, No. 269 Nanda Highway, Dashi Street ,Panyu , Guangzhou, Guangdongdong, China