導電率センサー
The Veswe Water Conductivity Sensor (VRS-EC-2-EX) accurately measures the conductivity of aqueous solutions. Equipped with a sophisticated automatic temperature compensation (ATC) function, it automatically converts readings to a standard reference temperature, ensuring accuracy in fluctuating thermal conditions.
Engineered for versatility, it offers two electrode material options—stainless steel for durability or plastic for corrosion resistance—paired with flexible RS485 (Modbus) or analog output signals. This configurable design makes it the perfect solution for a wide range of industrial, environmental, and water treatment applications.
- Model: VRS-EC-&-2-&-EX
- MOQ: 1 PCS
- 配達日:24時間以内
- 価格について今すぐ問い合わせる
お問い合わせEメール:contact@veswe.com|WhatsApp:+8613418148929

The Pulse of Your Water – The Intelligent
Water tells a story through its ions, and this Water Conductivity Sensor is the translator. Imagine a device that doesn’t just measure one thing, but sees the whole picture: Electrical Conductivity (EC), Salinity, Total Dissolved Solids (TDS), and Temperature, all in real-time. Visualize the sleek white conductivity transmitter housing standing firm against a splash of water, paired with an intelligent black controller displaying crisp, live data from your Water Conductivity Sensor. This isn’t just an EC sensor; it’s a comprehensive system anchored by a powerful Water Conductivity Sensor, designed for the heartbeat of municipal, industrial, and agricultural systems. Whether you are monitoring a pure mountain spring or a complex industrial effluent, this electrical conductivity meter for water gives you the immediate, trustworthy visibility you need. But remember, the true magic lies in the Water Conductivity Sensor itself.

Six Promises of Reliability – Why This Water Conductivity Sensor Stands Out
After a decade in sales, I’ve learned that you don’t buy hardware; you buy peace of mind. This Water Conductivity Sensor delivers exactly that through six core advantages. First, Measurement Precision: high-accuracy AD conversion ensures every drop of data from your Water Conductivity Sensor is reliable. Second, Strong Adaptability: whether it’s ultra-pure water or highly saline brine, this Water Conductivity Sensor adapts instantly. Third, Anti-Interference Ability: it resists the electromagnetic noise of heavy industry, acting as a steady conductivity monitor in chaotic environments. Fourth, Simple Operation: intuitive buttons mean no PhD required. Fifth, a Large LCD Display lets you see everything at a glance. And finally, Data Storage: it remembers history so you don’t have to. This is the robust, user-friendly Water Conductivity Sensor you’ve been waiting for—a true industrial conductivity meter built on the foundation of a superior Water Conductivity Sensor.

The Brain Behind the Data – Intelligent Controller for Your Water Conductivity Sensor
At the heart of this system lies a powerful microcontroller that does more than just read numbers; it understands the signals from your Water Conductivity Sensor. This unit performs complex calculations instantly, deriving Salinity and TDS from the raw EC values provided by your Water Conductivity Sensor while applying automatic temperature compensation. The display is a window into your water’s soul, showing the EC value, Temperature, and current output status directly from the Water Conductivity Sensor. With high intelligence built-in, this electrical conductivity sensor eliminates the need for external calculators. It’s a multi-parameter powerhouse that simplifies your setup, turning a complex lab analysis into a single, clear readout driven by your Water Conductivity Sensor. It’s the smartest Water Conductivity Sensor system on the market.

Built for the Elements – A Rugged Water Conductivity Sensor
Nature doesn’t always cooperate, but your Water Conductivity Sensor should. Encased in an IP65-rated fortress, this Water Conductivity Sensor is designed to withstand rain, snow, humidity, and the occasional splash. Picture the white conductivity transmitter box beaded with water droplets, protecting the sensitive Water Conductivity Sensor electronics within, while the probe remains partially submerged yet functioning perfectly. Labeled clearly as an “Industrial EC Transmitter,” it’s built for the tough life of pump stations and open channels. Unlike fragile lab instruments, this inline conductivity sensor is ready for the real world, ensuring long-term durability where other water conductivity sensors might fail. When you deploy this Water Conductivity Sensor outdoors, you are choosing protection you can trust.


Sensing the Unseen – The High-Precision Water Conductivity Sensor Probe
The true magic happens at the tip of your Water Conductivity Sensor. Our conductivity electrode is engineered for high sensitivity, detecting minute changes in ion concentration that others miss. Crafted with a stainless steel shaft and optimized for immersion, this EC probe—the heart of your Water Conductivity Sensor—offers strong anti-interference capabilities, keeping signals stable even amidst electrical noise. It boasts a long service life, resisting corrosion and fouling that plagues lesser conductivity probes. Whether your water is clean or moderately contaminated, this Water Conductivity Sensor delivers consistent, high-stability performance. It’s the diligent worker that never sleeps, ensuring your system always has the truth. A great system starts with a great Water Conductivity Sensor.
Clarity at a Glance – Large LCD Screen for Your Water Conductivity Sensor
Data from your Water Conductivity Sensor is useless if you can’t read it. That’s why this system features a generous 2.5-inch, 128×64 pixel LCD screen. It displays the current time, EC value, temperature, and current output simultaneously with crystal-clear digits, all sourced directly from your Water Conductivity Sensor. Whether you are standing right in front of the panel or viewing from across a large control room, the long viewing distance ensures you never miss a beat. This EC conductivity meter prioritizes visibility, making it ideal for remote monitoring stations where quick checks of your Water Conductivity Sensor are vital. No squinting, no guessing—just clear, actionable information from your Water Conductivity Sensor at your fingertips.

Guarding Your Data – Security Features of This Water Conductivity Sensor
In shared facilities or regulated industries, the data from your Water Conductivity Sensor is paramount. This system acts like a digital watchdog for your Water Conductivity Sensor. It features password-protected access, ensuring that only authorized personnel can tweak configuration menus, preventing accidental errors or data tampering with your Water Conductivity Sensor readings. Beyond security, it offers high-strength system protection against crashes, black screens, and interference-induced failures. Imagine a golden shield deflecting threats while your conductivity transmitter and Water Conductivity Sensor keep running smoothly. This layer of security makes it the perfect choice for critical applications where the integrity of your Water Conductivity Sensor data is non-negotiable.


Tailored Precision – Electrode Options for Your Water Conductivity Sensor
One size doesn’t fit all in water analysis. That’s why our Water Conductivity Sensor system offers two distinct electrode options to match your specific needs. Choose the Stainless Steel Electrode (K=1 for pure/tap water, K=10 for wastewater) for rugged durability, or the Plastic Housing Electrode for versatile applications. The Cell Constant (K) determines the range, allowing you to customize the probe of your Water Conductivity Sensor for everything from drinking water safety to heavy industrial discharge. This flexibility ensures that your Water Conductivity Sensor is perfectly tuned to your unique water chemistry, maximizing accuracy and lifespan. No matter your source, there is a Water Conductivity Sensor configuration for you.
Advanced Functions – The Smart Water Conductivity Sensor
This isn’t just a meter; it’s a historian and a strategist powered by your Water Conductivity Sensor. Equipped with a built-in RTC chip, this system displays the exact date and time, crucial for auditing the logs from your Water Conductivity Sensor. It also features internal memory capable of storing up to 3 days of historical data from your Water Conductivity Sensor, allowing you to retrieve trends and compliance reports effortlessly. Plus, its Intelligent Temperature Compensation works automatically across a wide range (-20°C to +60°C), ensuring your Water Conductivity Sensor remains accurate regardless of thermal fluctuations. These advanced features make this Water Conductivity Sensor the ideal choice for unattended, long-term deployment. Choose the Water Conductivity Sensor that works as hard as you do.

About - Water Conductivity Sensor
Conductivity sensors play a critical role in real time measurement of water conductivity, providing key parameters such as conductivity, salinity, and temperature. Whether you are monitoring water quality in industrial processes, environmental protection, or laboratory research, Renke conductivity sensors deliver the accuracy and performance you need to ensure reliable results. From standalone sensors to complete water quality monitoring systems, we offer a range of solutions tailored to different monitoring points, helping you achieve water quality monitoring with ease.
| Model | Material | Electrode constant | 測定範囲 | 決議 |
|---|---|---|---|---|
| RS-EC-*-2-SUSP01-EX | Stainless steel electrode | K=0.01 | 0.01~20μS/cm | 0.001μS/cm |
| RS-EC-*-2-SUSP1-EX | Stainless steel electrode | K=0.1 | 0.1~200μS/cm | 0.01μS/cm |
| RS-EC-*-2-SUS01-EX | Stainless steel electrode | K=1 | 1~2000μS/cm | 0.1μS/cm |
| RS-EC-*-2-SUS10-EX | Stainless steel electrode | K=10 | 10~20000μS/cm | 1μS/cm |
| RS-EC-*-2-EP01-EX | Plastic electrode | K=1 | 1~2000μS/cm | 0.1μS/cm |
| RS-EC-*-2-EP10-EX | Plastic electrode | K=10 | 10~20000μS/cm | 1μS/cm |
特徴
Our water conductivity sensor is composed of a data collector and an electrode. When using it, insert the conductivity electrode into the measuring liquid, and the data collector will send the data uploaded to our free platform or customer’s own platform through the RS485 signal or analog signal. Users can remotely view data in real time through a computer or mobile phone. To meet the needs of different users, our conductivity electrodes are available with four electrode constants. You can refer to the figure on the right and select the most suitable electrode type based on your monitoring environment.
データシート
| パラメータ | RS485 | 4-20mA/0-5V/0-10V |
|---|---|---|
| 電源 | DC 10~30V | |
| 消費電力 | 0.4W | 1W |
| 測定範囲 | K=0.01: 0.01~20μS/cm, K=0.1: 0.1~200μS/cm, K=1: 1~2000μS/cm, K=10: 10~20000μS/cm | |
| 精度 | ±1%FS | |
| 決議 | 0.001μS/cm (0.01~20μS/cm), 0.01μS/cm (0.1~200μS/cm), 0.1μS/cm (1~2000μS/cm), 1μS/cm (10~20000μS/cm) | |
| Temperature measure range | -20℃~100℃; Resolution: 0.1℃ | — |
| Temperature measure error | ±0.5℃ | — |
| Salinity measure range | K=0.01: 0~10ppm K=0.1: 0~100ppm K=1: 0~1000ppm K=10: 0~11476ppm | — |
| TDS measure range | K=0.01: 0~10ppm K=0.1: 0~100ppm K=1: 0~1100ppm K=10: 0~13400ppm | — |
| Temperature compensation range | -20℃~100℃ (default compensation temperature 25℃) | |
| Temperature compensation coefficient | default 0.02 | |
| 部品温度耐性 | -20℃~+80℃, 0%RH~95%RH (non-condensing) | |
| Electrode line length | default 5m (customizable 10m, 15m, 20m) | |
メリット
- Conductivity measurement range: 1~20,000 μS/cm; temperature measurement range: -20~100 °C.
- Built in salinity and TDS conversion functions.
- Wide voltage power supply, supporting DC 10 to 30 V.
- The data collector enclosure features a waterproof design with protection rated up to IP65, effectively preventing damage from rain and snow during outdoor use. The conductivity electrode has an IP68 protection rating, allowing it to operate reliably even in harsh environment.
動作原理
The water conductivity sensor working principle: when the conductivity electrode is in the solution, the electrode is equivalent to resistance, and the size of the resistance is inversely related to the conductivity of the solution. When the conductivity of the solution is fixed, the resistance of the electrode is proportional to the electrode constant K. Inverse relationship. Therefore, the measured value of the conductivity of the solution is calculated based on the resistance of the electrode and the constant K of the electrode itself and is obtained through temperature compensation.
申し込み
EC electrodes can be used with a waterproof data processor or with a digital display controller. Widely use in:
- River/ stream water quality
- Irrigation runoff water quality
- Salinity studies/Estuary monitoring
- Wastewater quality monitoring
- Aquaculture
FAQs - Water Conductivity Sensor
Conductivity refers to the ability to conduct current in a body of water. In water quality monitoring, conductivity is one of the important indicators reflecting the quality of water quality. When the conductivity value of the water is higher, the conductivity is better, and the TDS value in the water is larger. The TDS value represents the content of dissolved impurities in the water. The larger the TDS value, the higher the impurity content in the water. On the contrary, the smaller the impurity content, the higher the water Pure, the lower the conductivity.
The conductivity of water can be measured with a conductivity detector. Put the conductivity probe into the water. Calculate the conductivity value by measuring the change in solution resistance.
Water conductivity sensors are used in water-quality applications to measure how well a solution conducts an electrical current. This type of measurement assesses the concentration of ions in the solution. The more ions that are in the solution, the higher the conductivity.
In normal use, the electrode will not be scratched or corroded and can be used all the time. If the electrode is damaged, the measurement accuracy will be affected, and the electrode needs to be replaced in time.
The temperature compensation of conductivity is to compensate the conductivity value at the current temperature to the conductivity value at the specified temperature (default 25°C). The temperature coefficient is the percentage value of the change in the conductivity of the solution with the temperature, and the percentage change in the conductivity when the temperature rises by 1℃. The default 0.02 (2%) approximates the temperature coefficient of conductivity of potassium chloride solution. The user can set the temperature coefficient value by himself to make the temperature compensation more accurate. The method is to first set the temperature compensation coefficient of the device to 0, and then measure the conductance in the same solution to be tested at two different temperatures (t1, t2) Rate value (g1, g2), and then use the formula to obtain the change in conductivity per 1°C increase Δg=(g1-g2)/(t1-t2), and then measure the conductivity of the solution under test at 25°C, g0 , The temperature coefficient can be calculated as: α= Δg/g0.
It is recommended to calibrate with a standard solution close to the conductivity value of the solution to be tested. If the conductivity value of the solution to be tested is not clear, select a standard solution close to the middle value of the range.
- Under normal conditions, the sensor itself does not require routine maintenance. If a clear malfunction occurs, do not open or attempt to repair the sensor yourself. Please contact us as soon as possible.
- Before use, gently shake the conductivity electrode in the sample liquid to remove any air bubbles attached to the electrode surface. The measurement can then be performed normally.
- When the electrode is not used for a long period, it can generally be stored in a dry place. However, before reuse, it must be immersed in distilled water for several hours to activate the electrode. Electrodes that are used frequently may be stored in distilled water.
- Organic contamination on the electrode can be cleaned with warm water containing a mild detergent, or with alcohol. Calcium and magnesium deposits are best removed using a 10 percent citric acid solution.
- The electrode plates or pins should only be cleaned by chemical methods or by gently agitating them in water. Do not wipe the electrode plates or pins, as this may damage the platinum black coating on the electrode surface.
- The device should be calibrated before each use. For long term operation, calibration every three months is recommended. The calibration frequency should be adjusted according to application conditions, such as the level of fouling and chemical deposition.
- Do not immerse the cable connector in water before it is fully locked to the instrument connector.
For instruments with an electrode constant K = 1 and a measurement range of 1 to 10,000 μS/cm, use a 12,880 μS/cm standard solution for calibration.
For instruments with an electrode constant K = 10 and a measurement range of 1 to 100,000 μS/cm, use a 111,310 μS/cm standard solution.
During calibration, place the electrode into the standard solution after it has returned to room temperature. Gently agitate the electrode to speed up the response. Make sure the sensing section of the electrode is fully immersed in the solution and that no air bubbles are attached to the electrode surface. Then allow the system to stand still.
Once the conductivity reading has stabilized, adjust the electrode constant K according to the following formula:
Electrode constant K = (standard solution value ÷ current reading) × current electrode constant
The calibration is then complete.
It is recommended to use plastic conductivity electrodes for non-corrosive water, such as: hydrological observation, water plant treatment, aquaculture, etc.
It is recommended to use stainless steel conductivity electrodes for corrosive water, such as environmental protection pharmaceuticals, food processing, sewage treatment, etc.
- Submerged installation: the lead wire of the electrode passes through the stainless steel tube, and the 3/4 thread on the top of the electrode is connected with the stainless steel 3/4 thread with raw material tape. Make sure that no water enters the top of the electrode and the electrode wire.
- Pipeline installation: connect to the pipeline through the electrode 3/4 thread.
Our water conductivity sensor has been calibrated before leaving the factory. If you need to calibrate it later, you can find a solution with a known conductivity to calibrate it yourself. In the case of long-term use, it is best to calibrate once every three months.
Under normal conditions, the electrode has a one-year warranty and the data collector has a two-year warranty.
Please ntact us for the manual.
お問い合わせ
私たちの同僚ジャック
電話/ Whatsapp:+86 13418148929
Eメール:contact@veswe.com
住所:中国広東省広州市番禺区大石街南大街269号1-4階