Negatif İyon Dedektörü
This Veswe Negative Ion Detector features a color touch screen, providing real-time display of negative oxygen ion concentration in the air. It offers optional measurement elements, including temperature, humidity, formaldehyde, PM, and TVOC, adapting to diverse testing needs.
Equipped with optional data storage and USB disk export functions, the device adopts the standard MODBUS-RTU communication protocol and RS485 signal output, ensuring accurate, reliable measurement for professional testing scenarios.
- Model: VRS-NEGO-N01-2&-&-EX
- ADEDI: 1 ADET
- Teslim tarihi: 24 saat içinde
- Şimdi Fiyat Sorgula
Sorularınız için: E-posta: contact@veswe.com | WhatsApp: +8613418148929
About - Negative Ion Detector
The concentration of negative ions is one of the indicators of air quality. According to the World Health Organization, the standard concentration of negative oxygen ions in fresh outdoor air is 1,000~1,500 ions/cm³, while a healthy concentration indoors for urban residents ranges from 40~100 ions/cm³. The negative oxygen ion detector is used to monitor ion concentrations in sectors such as forestry, environmental protection, meteorology, and tourism, helping to improve air quality in both rural and urban areas. High-sensitivity negative ion detectors feature fast response times and are mainly used to measure the negative ion concentration in materials such as negative ion coatings and fabrics.
Negative ion detector description
This negative ion detector is powered by a rechargeable battery, featuring a compact design for easy portability, allowing users to measure negative oxygen ion concentrations at different locations. The color touchscreen enables real-time data viewing and allows users to manually set and adjust various parameters. The negative ion detector offers selectable measurement ranges of 0~5 million, 0~50 million, 0~100 million, 0~200 million, and 0~500 million ions/cm³. In addition to detecting negative oxygen ions, it can also be configured to measure temperature, humidity, formaldehyde (HCHO), PM2.5, and TVOC. It is suitable for both indoor monitoring and integration with weather stations.
Negative ion detector datasheets
| Güç kaynağı | DC18-30V or battery powered | |
| Battery capacity | 4000mAh | |
| Çalışma ortamı | -20℃~50℃; <95%RH no condensation | |
| Depolama kapasitesi | 65535 readings | |
| Şarj süresi | ≤4h | |
| Pil çalışma süresi | 10h | |
| Negative oxygen ion parameters | Ölçüm aralığı | 0-5 million ions/cm³ (Optional 50,000/100,000/500,000/50 million) |
| Minimum resolution | 10 ions/cm³ | |
| Ölçüm hatası | ±15% | |
| Data update frequency | 1Hz | |
| Ion mobility | 0.4cm²/(V*S) | |
| Ion mobility error | ±5% | |
| Sıcaklık | Ölçüm aralığı | -40℃~60℃ |
| Doğruluk | ±0.5℃(25℃) | |
| Çözünürlük | ≤0.1℃/y | |
| Nem | Ölçüm aralığı | 0%RH~100%RH |
| Doğruluk | ±3%RH(60%RH,25℃) | |
| Çözünürlük | ≤1%RH/y | |
| PM10/PM2.5 | Ölçüm aralığı | 0~1000ug/m³ |
| Doğruluk | ±3%FS(@100μg/m³,25℃) | |
| Çözünürlük | 1ug/m³ | |
| CH₂O | Ölçüm aralığı | 0~2ppm |
| Doğruluk | ±0.025ppm or ±20%FS | |
| Çözünürlük | 0.001ppm | |
| TVOC | Ölçüm aralığı | 0~60000ppb |
| Doğruluk | 15%FS(@C2H6O,0.5ppm,25℃,50%RH) | |
| Çözünürlük | 1ppb | |
Negative ion detector zero adjustment
When the negative ion detector operates for an extended period, measurement inaccuracies may occur. In such cases, zero calibration is required. First, on the main interface, tap “System Settings”, then select “Negative Oxygen Ion Settings” from the system menu.
In the “Negative Oxygen Ion Settings” interface, tap “Device Zero Calibration”, and enter the zeroing password: 1234321. Next, cover the air inlet with the provided cap. After a 60s countdown on the screen, the device will automatically return to the main interface, with the working status showing “Zeroing…”. Wait until the status changes to “Measuring…”, then remove the air inlet cover — zero calibration is now complete.
U disk export data
veswe pm sensor can long-term uninterrupted monitoring of PM2.5 and PM10, accurate and stable performance. Supporting mobile phones and PC to check the data at any time. Very convenient for customers.
Bakım
1. The collector, air inlet and outlet, fan, etc. should be cleaned once a month.
2. At least three months, a special inspection and cleaning, and maintenance of the collector, circuit, and gas circuit should be carried out.
3. Before the lightning-prone season of each year, the lightning protection grounding, the collector shell, and the outer box grounding should be inspected and maintained.
FAQs - Negative Ion Detector
Negative oxygen ions are the free electrons generated by the ionization of molecules in the air under the action of high pressure or strong rays, and most of the free electrons are obtained by oxygen. One type of negatively charged oxygen ions (the electrons are negatively charged) that gain some electrons are called “negative oxygen ions“, and the other is the health killer superoxide radical.
The negative oxygen ions in the air have a good effect on the environment and the maintenance of human health. In medicine, negative oxygen ions are known as “vitamins in the air” and “longevity factor”. They can effectively decompose and reduce harmful gases in the air, making people feel refreshed and refreshed, enhancing skin elasticity, relieving aging, preventing health. They can improve respiratory diseases and cardiovascular and cerebrovascular diseases, lower blood pressure, increase appetite, and regulate the body’s physiological functions.
- Çevresel İzleme
Used for real-time assessment of air quality in eco-tourism areas, forest parks, and similar regions by providing negative oxygen ion concentration data to support air freshness certification. - Indoor Air Quality Assessment
Capable of simultaneously detecting pollutants such as formaldehyde and PM2.5, making it suitable for home renovation acceptance inspections and air purifier performance testing. - Industrial Product Development
Helps manufacturers quantify the efficiency of negative ion release, optimize air purification technologies, and support marketing efforts for products like nano coatings and health-related items. - Agricultural and Storage Management
Equipped with temperature and humidity monitoring functions, suitable for greenhouse environmental control and storage condition monitoring.
- Color display screen with an elegant and modern appearance.
- Equipped with a high-precision negative oxygen ion measurement unit, ensuring long-term stability and minimal drift.
- Built-in dedicated RS485 circuit with standard ModBus-RTU communication protocol; both communication address and baud rate are configurable.
- Integrated battery with optional external power supply via a wide DC voltage range of 18–30V.
- Optional data storage function with USB export capability.
- Optional sensors include formaldehyde (HCHO), PM2.5/PM10, temperature and humidity, and TVOC.
- Touchscreen settings for user-friendly and efficient operation.
Air negative ion concentration refers to the number of negative ions per unit volume of air, and its unit is ions/cm³.
The overall structure of the negative ion detector is composed of 3 concentric cylinders. The outer cylinder body and the inner shaft are electrodes. When air passes through the cylinder, the ions hit the cylinder body and the shaft to generate discharge, and the discharge signal is recorded, so that it can be positive in the air. , The number and size of negative ions are measured.
- After powering on the negative oxygen ion detector, select the working mode. There are three options: low range, high range, and automatic range switching.
- For example, for a device with a 0~5 million range, the low range mode can measure negative oxygen ion concentrations within 0~300,000 ions/cm³. The high range mode can measure concentrations within 0~5 million ions/cm³. However, within the 0~300,000 range, the accuracy is lower, and there is no intermediate range.
- In automatic range switching mode, the measurement range is 0~5 million with high accuracy, but when the value exceeds 300,000 ions/cm³, there will be a one-minute delay for range switching.
- Note: When selecting different range modes for measurement, zero calibration is required.
- Can be fixed using screws; the mounting hole diameter is 4.5mm. It is important to ensure the negative oxygen ion detector is placed vertically, with the air inlet and outlet unobstructed to avoid affecting data accuracy.
- Installation must be stable, with the detector center positioned at a height of 1.5 meters from the ground.
- The collector’s housing and outer enclosure should have proper grounding.
- Equipped with lightning protection facilities; grounding resistance should be less than 4Ω.
- Optional protective fencing can be installed; fence height should not exceed 1.2 meters, and the distance between the instrument and the fence should be greater than 2.0 meters.
You can contact us to get the manual by leaving a message or email.
Sektör Bilgisi
En İyi 3 Su Kalitesi Parametresi Türü | Veswe Su Kalitesi İzleme Sensörleri
Bize ulaşın
Meslektaşımız: Jack
Telefon / Whatsapp: +86 13418148929
E-posta: contact@veswe.com
Adres: Kat 1-4, No. 269 Nanda Otoyolu, Dashi Caddesi, Panyu, Guangzhou, Guangdongdong, Çin